LEGERFIBRE TYPE I AND II

The Legerfibre system consists of a factory-laminated LEGERTOIT or LEGERPENTE TYPE I or TYPE II insulation panel, plus a BP ESGARD ½ in wood fiber panel.

Download the data sheet

Length and width

  • 4’ x 4’ (1219 mm x 1219 mm)
_
PHYSICAL PROPERTIES Imperial Metric ASTM Test EPS Type 1 EPS Type 2 EPS Type 2 (1.5 HD)
Thermal resistance: R-value at 75ºF (24ºC) for 1 in (25 mm) thickness
h.pi2 hre°F
BTU
m2 °C
W
C-518
C-177
3.7 min.
(0.70 min.)
4.0 min.
(0.70 min.)
4.17 min.
(0.73 min.)
Compressive strength (min.) at 10% distortionlb/po2 ou psi(kPa)D-162110.2 (70)16 (110)20.4 (140)
Bending strength (min.)lb/po2 ou psi(kPa)C-20325 (170)35 (240)43.6 (300)
Dimensional stability: % of linear change (max.)%%D-21261.51.51.5
Coefficient of thermal expansion (max.)po/po/°F(mm/mm/°C)D-6963.5 x 10-5 (6 x 10-5 C-1)3.5 x 10-5 (6 x 10-5 C-1)3.5 x 10-5 (6 x 10-5 C-1)
Water vapor permeability (max.)Perm-Po(ng/Pa.s.m2)E-965.25 (300)3.5 (200) 
Water absorption (max.)%%D-2842643
Effective temperature range
- Continuous
- Intermittent
 
°F
°F
 
(°C)
(°C)
 
-
-
 
167 (75)
180 (82.2)
 
167 (75)
180 (82)
 
167 (75)
180 (82.2)
Flame spread rating--CAN/ULC S102,2 M)<115<140<140
Generated smoke --CAN/ULC S102,2 M)--<380
Capillarity-----Nil
 

Permanent R-Value Guarantee

The thermal resistance of this type of insulation is permanent due to its cellular structure which contains only stabilized trapped air. EPS performance does not diminish over time.

Installation

Insulation panels can be applied hot or cold, as needed, using bitumen cooled to 225°F or fixed to the surface mechanically.

Evaluation

LEGERLITE INSULATION :

  • Certified INTERTEK ETL SEMKO
  • Conforms to CAN/ULC-S701-01 standards
  • Conforms to CAN/ULCS-126M DSIGN C7,C12
  • Conforms to Association des maîtres couvreurs du Québec standards

Notes

notes

EPS beads should be considered flammable when subjected to a source of intense heat or a constant strong flame. They are vulnerable to petroleum-based solvents and prolonged exposure to ultraviolet radiation.


BP ESGARD

Length and width

  • 4’ x 4’ (1219 mm x 1219 mm)

Evaluation

BP ESGARD WOOD FIBER:

  • Conforms to CAN/ULC –S126-M86 design C2, C7, C12, C25
  • Conforms to CAN/ULC –S107#CR771 classes A and C
  • CCMC 03240-L (except 4’ x 8’ panels)
_
TEST ASTM normalized
testing methods
ESGARD 1/2
Imperial
ESGARD 1/2
Metric
Thickness-0.50 po12.70 mm
Linear expansionD-10370.50 %0.50 %
Water absorption (2 h)D-10373.75 % vol.3.75 % vol.
Thermal resistanceC-5181.63 R0.29 RSI
Thermal conductivityC-5180.31 K0.045 KSI
Transverse strengthC-20910.93 lb/po248.61 N
Parallel strengthC-209223.94 lb/po21544.00 KPA
Perpendicular strengthC-2094.20 lb/po228.96 KPA
Compressive strength at 10% distortionC-16518.6 lb/po2128.24 KPA
Modulus of rupture (MOR)D-2164237.40 lb/po21636.81 KPA
DensityD-103715.00 lb/po3240.28 kg/m3
DeflectionC-2090.55 po.13.97 mm